  4. Electronic thermostat EUROSTER 11 C to control a central heating system pump

Electronic thermostat EUROSTER 11 C to control a central heating system pump

EUROSTER 11 C Electronic thermostat to control a central heating system pump Euroster 11C is an electronic central heating circulation pump controller... celý popis
Product number:EUROSTER 11 C
Manufacturer:Euroster
Complete specification

EUROSTER 11 C

Electronic thermostat to control a central heating system pump

Euroster 11C is an electronic central heating circulation pump controller designed for automatic switching on and off of the circulation pump in accordance with the set temperature. The regulator - pump assembly is intended for forcing water circulation in central heating installations with a coal or gas boiler (without a pump control system). The sensor used in the regulator measures the water temperature at the heating system flow. In the central heating installation with a coal boiler, the regulator switches off the circulation pump after the boiler flame goes out. In a central heating system with a gas boiler, the temperature set on the regulator must be lower than the temperature set on the boiler thermostat. Setting the regulator knob to a temperature above the dew point prevents the boiler from getting wet during water heating. Maximum power consumption: 1.4 kW.

Advantages:

  • Device for controlling the central heating pump in heating installations
  • Automatic switching on and off of the circulation pump according to the set temperature
  • Cooperation with circulation pamphas for solid or gas boilers (without pump control system)
  • Temperature measurement using a sensor that measures the water temperature at the heating flow
  • In the central heating installation with a solid fuel boiler, the regulator will switch off the circulation pump after the boiler flame has extinguished.
  • Setting the temperature above the dew point prevents the boiler from sweating during heating the water in central heating
  • The Anti Stop System, which prevents the seizing process of the unused pump impeller, which starts the circulation pump (also outside the heating season) for approx. 30 seconds every 14 days

Technical parameters:

Controlled devicecentral heating pump
Supply voltage230 V 50 Hz
Maximum load on each output3 A 230 V 50 Hz
Power consumption1.4 watts
Temperature measurement rangefrom -5 ° C to + 90 ° C
Temperature adjustment rangefrom + 5 ° C to + 90 ° C
Accuracy of temperature control5 ° C
Hysteresis rangefrom 5 ° C
Visual signalingLEDs
Working temperaturefrom + 5 ° C to + 40 ° C
Storage temperaturefrom 0 ° C to + 65 ° C
Level of securityIP 40
Colourblack
Mounting methodwall, wall plugs
Driver mass with cables0.52 kg
Standards, approvals, certificatescompliance with EMC and LVD directives
Warranty2 years
Dimensions (width / height / depth) 150 mm / 90 mm / 52 mm
EquipmentEuroster 11C controller, wall plugs, manual, mounting template, sensor band

 