Adex Comfort R – regulation for reverse protection, classic heating

Adex Comfort R 1. Heating system with boiler temperature control This connection can be used for boilers for which it is necessary to maintain the rec... celý popis
Product number:125007
Manufacturer:Adex
Complete specification

Adex Comfort R

1. Heating system with boiler temperature control

This connection can be used for boilers for which it is necessary to maintain the recommended operating temperature. They can be solid fuel and gas boilers because the boiler outlet temperature is regulated by controlling the temperature drop on the radiators, it is also possible to reliably operate heating systems with imperfect circulation in the boiler circuit. The controller can also handle installations where the boiler circuit is not created at all.

The controller thus maintains the required boiler temperature for a system with both a four-way and a three-way mixing valve. In the case of a system, the four-way valve and the boiler pump then also indirectly ensure that the required minimum boiler water return temperature is maintained.

Domestic water heating is provided in winter and summer mode.

2. Solid fuel boiler room with a backup boiler in the heating circuit

If the temperature of the solid fuel boiler is insufficient, the controller closes the mixing valve and switches to operation with a backup boiler. The backup boiler then switches in a 10-minute cycle to maintain the desired temperature in the heating circuit.

The backup boiler can be electric or gas and must be equipped with its own circulation pump. The gas boiler must be sufficiently resistant to low-temperature corrosion.

DHW is heated only by a solid fuel boiler. The temperature of the tapped water can be regulated by a thermostatic mixing valve installed at the outlet of the boiler.

3. Solid fuel boiler room with a backup boiler in the boiler circuit

The connection can be used for single and multi-circuit heating systems with a backup boiler. The backup boiler can be gas or electric. If the temperature of the solid fuel boiler is insufficient, the controller switches to operation with a backup boiler. The backup boiler is permanently switched on, the temperature in the heating circuit is regulated by a mixing valve.

Domestic water heating is provided in winter and summer mode.

4. Solid fuel boiler room with storage tank and backup boiler

In the basic connection, the controller ensures the supply of heat from the solid fuel boiler directly to the building. Only surpluses that the building does not need are stored in the storage tank.

With the "Only for discharging the battery" connection, the controller only heats the building if the storage tank is charged to the required temperature.

If the temperature in the storage tank and in the solid fuel boiler is insufficient, the controller checks whether the tank is discharged to the temperature selected by the user. If so, the controller closes the mixing valve and switches to operation with a backup boiler.

Thus, the user can determine the discharge rate of the storage tank. Before switching on the backup boiler, the storage tank is always discharged to at least the temperature specified by the user.

The backup boiler can be electric or gas and must be equipped with its own circulation pump. The gas boiler must be sufficiently resistant to low-temperature corrosion.

5. Boiler room for solid fuels with storage tank with the possibility of connecting a boiler for controlled DHW heating

In the basic connection, the controller supplies heat from the boiler directly to the building. Only surpluses that the building does not need are stored in the storage tank.

With the "Only for discharging the battery" connection, the controller only starts heating the building after the storage tank has been charged to the required temperature.

If the tank is discharged, the controller switches off the circulation pump, closes the mixing valve and waits for a new flooding in the boiler.

It is possible to connect a DHW heater with a charging pump to the storage tank. The controller then switches the charging pump according to the DHW thermostat and with respect to the temperatures on sensors K and V.